Free calculator

Water Pipe Size Calculator

Enter the flow in gallons per minute. You get the water speed in every size of copper or PEX, and the smallest pipe that stays under your speed limit.

Size the line

Pipe size from flow (GPM)

Enter the flow the line has to carry. The calculator works out the water speed in each size and picks the smallest pipe under your limit. Nothing you type leaves your browser.

GPM

Add up the fixtures that run at the same time. A shower head is 2.5 gpm or less and a kitchen faucet 2.2 or less.

ft/s

8 ft/s for cold and 5 ft/s for hot are the common limits. Type a lower number for a quieter line.

Check a pipe

Water velocity in the pipe

Already know the pipe? See how fast the water moves in it, and the most flow it carries at 5 and 8 ft/s.

GPM

Follows the flow above until you change it here.

Inside diameter-
Most flow at 5 ft/s-
Most flow at 8 ft/s-
Water speed-

Result

-

Fill in the flow above.

Water speed in each size
SizeInside (in)Speed (ft/s)Under limit
1/2 in0.545--
3/4 in0.785--
1 in1.025--
1-1/4 in1.265--
1-1/2 in1.505--
2 in1.985--

Sized by water speed only. Long runs also lose pressure to friction: confirm the size with your local plumbing code.

Copper pipe size chart

Pipe size for a water line comes down to how fast the water moves. Push too many gallons through a small pipe and the water runs fast enough to bang, whistle and wear through copper at the elbows. The calculator above works out the speed in each size and picks the smallest one under your limit.

The speed comes from one formula: velocity in ft/s = 0.4085 x GPM / (inside diameter in inches, squared). That is why the inside diameter matters, not the size printed on the pipe. Copper tube comes in three wall weights. Type K has the thickest wall, type L is the common choice for water lines in a house, and type M is the thinnest. All three share the same outside diameter, so they take the same fittings, but the hole through the middle is different.

Copper tube (ASTM B88): most flow in type L, and sizes in inches

SizeGPM at 5 ft/sGPM at 8 ft/sOutsideInside KInside LInside M
1/2 in3.65.80.6250.5270.5450.569
3/4 in7.5120.8750.7450.7850.811
1 in12.820.51.1250.9951.0251.055
1-1/4 in19.531.31.3751.2451.2651.291
1-1/2 in27.744.31.6251.4811.5051.527
2 in48.277.12.1251.9591.9852.009

Swipe the chart sideways for the outside and inside diameters.

Worked example: 8 gpm through 3/4 inch type L copper is 0.4085 x 8 / 0.785 squared = 5.3 ft/s. That is under 8 ft/s, so 3/4 inch works on a cold line. A hot line held to 5 ft/s needs 1 inch, which runs 3.1 ft/s. Half inch would run 11 ft/s, too fast for either.

PEX pipe sizing chart

PEX for water lines is made to copper tube size (CTS), so 3/4 inch PEX has the same 7/8 inch outside diameter as 3/4 inch copper. The wall is thicker (SDR-9), so the inside is smaller and the same flow moves faster. On a busy run, plan on PEX one size up from copper.

PEX tubing (CTS, SDR-9): most flow, and sizes in inches

SizeGPM at 5 ft/sGPM at 8 ft/sOutsideInside
1/2 in2.74.40.6250.475
3/4 in5.58.80.8750.671
1 in914.51.1250.862
1-1/4 in13.521.71.3751.054
1-1/2 in18.930.31.6251.244
2 in32.451.92.1251.629

Swipe the chart sideways for the outside and inside diameters.

Worked example: the same 8 gpm through 3/4 inch PEX is 0.4085 x 8 / 0.671 squared = 7.3 ft/s. It passes an 8 ft/s cold limit; on a hot line, 1 inch PEX at 4.4 ft/s is the size. At 10 gpm, 3/4 inch PEX runs 9.1 ft/s, so even the cold line moves up to 1 inch (5.5 ft/s).

Speed is one check, not the whole design

This page sizes by water speed only. A long run also loses pressure to friction and to every fitting, and a house main is sized from the fixtures on it, using the fixture-unit tables in your local plumbing code (IPC or UPC). Use the speed check to catch a pipe that is too small, then confirm the size against your code and the pipe maker's limits before you rough in.

From pipe sizes to a price

Once the sizes and the footage are set, the material list is easy to price. The plumbing pricing guide covers labor rates and markup, and a plumbing estimate template puts the job in front of the customer.

Common questions

For a cold water line in type L copper, 3/4 inch: it runs 6.6 ft/s, under the common 8 ft/s limit. A hot line held to 5 ft/s needs 1 inch (3.9 ft/s). In PEX, 10 gpm needs 1 inch for cold water (5.5 ft/s) and 1-1/4 inch for hot (3.7 ft/s), because PEX has a smaller inside diameter.

The common limits are 8 feet per second for cold water and 5 feet per second for hot water, with very hot recirculating lines kept slower still. Faster water is noisy, adds water hammer and wears through copper at elbows and tees. Check the limits your local code and the pipe maker use.

At 8 ft/s, 3/4 inch type L copper carries about 12 gpm and 3/4 inch PEX about 8.8 gpm. Held to 5 ft/s for hot water, it is 7.5 gpm in copper and 5.5 gpm in PEX. The charts on this page list every size from 1/2 to 2 inch.

On the outside, yes. PEX for water lines is copper tube size, so 3/4 inch PEX and 3/4 inch copper are both 7/8 inch across. The PEX wall is thicker, so the inside is smaller (0.671 inch against 0.785 inch for type L copper) and PEX carries less water at the same speed.

Wall thickness. All three share the same outside diameter and fittings. Type K is the thickest and is used underground and for water services, type L is the common choice for water lines inside a house, and type M is the thinnest. Which types are allowed where is up to your local code.

No. Nothing you type is transmitted or stored - the math runs in your browser. There is no account and no email.

More free contractor tools

What gauge for the amps and distance

Wire Size Calculator

The smallest copper or aluminum wire, 14 AWG to 4/0, for the load and the run.

Volts lost on a long run

Voltage Drop Calculator

Copper or aluminum, single or three phase, with a chart of every size from 14 AWG to 4/0.

Saturation pressure for 4 refrigerants

Refrigerant PT Chart

R-22, R-410A, R-454B and R-32 every 5 °F, with bubble and dew columns for the blends.

A 30% markup is not a 30% margin

Markup vs Margin Calculator

Convert between the two, and find the markup that lands the margin you want.

What to charge per hour

Hourly Rate Calculator

Work back from the take-home you want, your overhead, and the hours you can actually bill.

From pipe sizes to a signed plumbing job

FastEstimateMaker turns the job into a priced plumbing estimate in about a minute, then tracks it, collects the signature and the deposit, and invoices the job. Start free - no credit card required.

Build a real estimate free

Solo is $29.99/month with every office feature. Canvass is $59.99/month plus $19.99/month per rep seat.